TARKO — Pumps | Pipes | Cables & Wires
    INTERMEDIATE 7 min read22 June 2026

    Complete HDPE Pipe Size Chart: DN 20mm to DN 630mm as per IS 4984:2016

    Full reference table of HDPE pipe outer diameter, wall thickness, SDR, pressure rating and weight per metre as per IS 4984:2016 for PE 100 grade SDR 11 pipes.

    This article provides a complete HDPE pipe dimension reference based on IS 4984:2016. All values below are for PE 100 grade, SDR 11 — the most commonly specified combination for water supply in India.

    Understanding the Dimensions

    • OD (Outer Diameter): The outside diameter in mm — this is how HDPE pipes are sized in India (OD-based system)
    • Wall thickness (e): Minimum wall thickness at the thinnest point of the pipe cross-section
    • SDR: Standard Dimension Ratio = OD ÷ wall thickness. SDR 11 = relatively thick wall
    • Pressure rating: PN 12.5 for PE 100 SDR 11 (same pipe is PN 10 for PE 80 SDR 11)
    • Weight: Approximate weight per metre of pipe in kg

    HDPE Pipe Dimensions — PE 100, SDR 11

    OD (mm)Wall Thickness (mm)SDRPressure (PE 100)Weight (kg/m)
    202.011PN 12.50.117
    252.311PN 12.50.172
    323.011PN 12.50.282
    403.711PN 12.50.436
    504.611PN 12.50.676
    635.811PN 12.51.069
    756.911PN 12.51.511
    908.211PN 12.52.163
    11010.011PN 12.53.207
    12511.411PN 12.54.160
    14012.811PN 12.55.220
    16014.611PN 12.56.806
    18016.411PN 12.58.607
    20018.211PN 12.510.616
    22520.511PN 12.513.428
    25022.811PN 12.516.577
    28025.511PN 12.520.774
    31528.711PN 12.526.286
    35532.311PN 12.533.375
    40036.411PN 12.542.363
    45041.011PN 12.553.630
    50045.511PN 12.566.122
    56051.011PN 12.583.004
    63057.311PN 12.5104.974

    Coil vs Straight Lengths

    Size RangeStandard FormCommon Lengths
    DN 16 to DN 63Coil50 m, 100 m coils
    DN 75 to DN 160Coil or straight50 m coil or 6 m / 12 m lengths
    DN 180 and aboveStraight lengths6 m or 12 m lengths

    For borewell rising mains, DN 50mm to DN 110mm (SDR 11, PE 100) covers most Indian submersible pump configurations. For sprinkler mainlines, DN 63mm to DN 160mm (SDR 17, PN 6) is the standard range.

    How to Order HDPE Pipes

    Always specify the pipe using the IS 4984:2016 designation format: PE [grade] / PN [pressure] / DN [diameter] / SDR [ratio]. Example order: PE 100 / PN 12.5 / DN 110 / SDR 11 / IS 4984:2016. This ensures you get exactly what you need and can verify ISI certification.

    Full IS 4984 Size Range

    IS 4984:2016 covers DN 16mm to DN 2500mm. The table above covers the most commonly available sizes. Larger diameters (DN 710mm to DN 2500mm) are manufactured for major municipal and industrial projects on order, in five size groups: Group I (16–180mm), Group II (200–500mm), Group III (560–1000mm), Group IV (1200–2000mm), Group V (2250 & 2500mm).

    Pipe Size ChartODWall ThicknessIS 4984PE 100

    Need Help Choosing the Right Pipe?

    Our team at TARKO will help you select the correct size, SDR and pressure rating for your project.